August 04, 2017

How To Use BMW INPA Software

Loooong post here....


BMW INPA how to use- with frequently asked questions:


INPA EDIABAS download:

Inpa diver.zip(unknown security)

Inpa 5.0.1.zip(unknown security)

Inpa 5.0.2.zip(tested & worked on Windows XP)


INPA cable: K+DCAN cable switch mode:

Old K+Dcan cable vs K+DCAN cable switch mode:


Credits to BMW Group!

I take no credit for composing the package, just sharing it


Table of Contents

1. EDIABAS Error Messages.............................................................................................. 4

1.1 Driver Error................................................................................................................... 4

1.2 DirectNt.sys can’t be opened........................................................................................ 4

1.3 IFH-0002: Interface isn’t connected or doesn’t respond................................................ 4

1.4 IFH-0003: Data transmission HOST/Interface failed..................................................... 4

1.5 IFH-0010: Data transmission to control unit disturbed .................................................. 5

1.6 IFH-0013: Command not implemented......................................................................... 5

1.7 Error: EBAS32.EXE not found or illegal version! .......................................................... 5

1.8EDIABAerror: Error (95) SYS-0005: OBJECT FILE NOT FOUND ............................ 6

1.9 Createfile_error: OPEN CONNECTION; IFH 0018- INITIALIZATION ERROR............. 6

1.10 Battery and Ignition notrecognised.............................................................................. 6

1.11 Warning when starting OBD Setup............................................................................... 7

1.12 ERROR C1015: Too Many String Variables in Job....................................................... 8

1.13 Failure: EDIABAS Fehler 159, NET-0009: TIMEOUT................................................... 8

1.14 Failure: The name of the file or folder can’t be changed............................................... 9

2 Error Message INPA...................................................................................................... 10

2.1 APLDLL or API32.DLL can’t be found. ....................................................................... 10

2.2 Error Message 0020: Incorrect or Missing Driver. Theprogrammewill be aborted!.... 12

2.3 SYS-00002: ECU variation description file not found.................................................. 12

2.4 INPA Error: Error at Compiling à Abort! .................................................................... 13

2.5 IFH-0018:InizialisationError –INPAdoesn’t work but Toolset yet ............................. 14

2.6 IFH-0027: IFH not found à The Programm was aborted! .......................................... 14

2.7 INPA Error: Opening Inpa – Transmission error returned a_0x2 ................................ 15

2.8 INPA Error: Only a white screen appears when you run INPALOAD.EXE. ................. 15

2.9 INPA Error: DTM is no longer supported .................................................................... 16

2.10 INPA Error: Bridge16.exe can’t be initialised .............................................................. 16

2.11 Error when opening the error file à abort:.................................................................. 17

2.12 Compiler: File: \INPA\DEUTSCH\***.OUT not found! ................................................. 17

3 Tool Set Error Messages.............................................................................................. 18

3.1 EDIABAS error 100: SYS-0010: INITIALIZATION ERROR ........................................ 18

3.2 EDIABAS Error 126 (only up to Ediabas V6.4.x)......................................................... 18

3.3 IFH-0006: Command not accepted and IFH-0018: Initialization Error and IFH-0038:

Interface Command not implemented......................................................................... 18

3.4 IFH-0006: Command not accepted............................................................................. 19

3.5 IFH-0009: ECU isn’t connected or doesn’t respond.................................................... 20

3.6 SYS-0002: ECU OBJECT FILE NOT FOUND............................................................ 20

3.7 SYS-0005: Controller description file not found. Theprogrammewill be aborted! ...... 20

3.8 ToolSet Error: Runtime error ’372’.............................................................................. 21

3.9 Tool Set Error: Run-time error ’5’ – Invalid Procedure Call ......................................... 21

3.10 Tool Set Problem: If an SGBD is opened, then only the hourglass appears and the

SGBD is not loaded. ................................................................................................... 21

3.11 EDIABAS error 20: IFH-0010: Data transmission to control unit disturbed ................. 21

3.12 EDIABAS Error 134: API-0014: Result not found ....................................................... 22

3.13 It takes too long to load an SGBD in the Tool Set ...................................................... 22

3.14 Black Windows in the Tool Set ................................................................................... 22

4 General Questions
........................................................................................................ 23

4.1 Installation of EDIABAS and INPA.............................................................................. 23

4.2xBD-Export of SGBDs, Group SGBDs, INPA scripts and INPA configuration files using

the ECCO Web Client ................................................................................................ 23

4.3 How can I find out if the serial interface COM1 has been taken?................................ 25

4.4 How do I start INPA?.................................................................................................. 26

4.5 How can I switch between OBD and ADS interfaces? ................................................ 26

4.6 In which directory structure is OBD.ini saved?............................................................ 27

4.7 How can I find out what interface I installed with INPA? ............................................. 27

4.8 How do I find out what EDIABAS package is installed?.............................................. 27

4.9 How can I uninstall EDIABAS or INPA?...................................................................... 27

4.10 How can tell if the EDIABAS server is running as a 16-bit or a 32-bit application? ..... 27

4.11 What is the difference between \EDIABAS\bin\ToolSet.exe and

\EDIABA\bin\Tool32.exe?........................................................................................... 28

4.12 What is an SGBD and what is its connection to EDIABAS? ....................................... 28

4.13 Where are the individual SGBD names and theirmeanings givenin plain English?... 28

4.14 What is a Job? ........................................................................................................... 28

4.15 What do SGBDs with the name _xxx mean?.............................................................. 29

4.16 What is the group file used for?.................................................................................. 29

4.17 Diagnostics Index ....................................................................................................... 29

4.18 Variation Index ........................................................................................................... 29

4.19 What is the meaning of the file EDIABAS.ini? ............................................................ 29

4.20 How is the simulation file connected to the trace file?................................................. 31

4.21 Why have an XBD Generator? ................................................................................... 31

4.22 What are the prerequisites for remote access via TCP/IP? ........................................ 31

4.23 What is the VC Tool and when is it used? .................................................................. 32

4.24 What is the KVP Editor?............................................................................................. 32



1.1 Driver Error

Messagecomes along with an ADS or OBD connector.

This error occurs if another program or device has taken the COM1 port of your PC.

If you want to work with EDIABAS or INPA, please make sure that the COM1 port is not

taken.

1.2 DirectNt.sys can’t be opened

This error only occurs with an NT computer if the ADS driver hasn't been installed.

The instructions for installing the ADS driver can be found in the "Installation Guide/Update

Guide” ADS_DOKU.pdf in the directory C:\EDIABAS\Hardware\ADS\ or on the Intranet page

http://www5.muc/ti4-web/ti-430/german/themen/Diagnose.htm.

1.3 IFH-0002: Interface isn’t connected or doesn’t respond

Reason: In the Ediabas.inifile, the interface is set toSTD:FUNK. However, you have

connected an ADS or OBD connector.

Solution: Modify the interface setting in Ediabas.ini.

1.4 IFH-0003: Data transmission HOST/Interface failed

Reason 1: In the Ediabas.inifile, the interface is set toSTD:OBD. However, you have

connected an ADS connector.

Solution 1: Modify the interface setting.

Reason 2: The data transmission failed when sending (e.g. short circuit in the line).

Solution 2: Get rid of the short circuit, for example.

Reason 3: Connector not connected or no power supplied.

Solution 3: Check whether the connector is connected and is supplied with power.

Reason 4: The device manager has been used to disable the FIFO buffer for COM1.

Solution 4: In the device manager (Windows XP: Enter "Start” à "Control Panel” à

"System” à "Hardware” à "Device Manager” à Ports (COM & LPT)), and then

select COM1 from the ports. Then under the "Port Settings” tab, select

"Advanced”. There must be a check-mark by "Use FIFO buffers” and "8” must be

selected for the receive buffer and transmitpuffer.

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage5of32

TI-430 Andreas Schandl Release date: 29.09.2006

1.5 IFH-0010: Data transmission to control unit disturbed

This problem can occur with XP computers with the OBD interface.

Reason: With Windows XP, it is not possible to automatically set the receive and transmit

buffers using OBDSetup.exe, like in Windows NT.

Solution: Set the receive and transmit buffers to 8 as shown in the following:

Use Start à My Computer à Control Panelà System à Hardware à Device

Manager à Ports (COM & LPT) and then clickwiththe right mouse button to call

up the properties of the COM port that is being used. Under the Port Settings tab,

set the Data bits of the receive and transmit buffers to 8.

1.6 IFH-0013: Command not implemented

Reason: The error was caused by anotherprogrammethat accessed the COM1 interface.

Usually, the "HotSync”programmeis installed on the computer for theorganiser.

Solution: Check theprogrammesthat are started automatically when Windows is started.

1.7 Error: EBAS32.EXE not found or illegal version!

This error occurs if the path variable is setwiththe path C:\EDIABAS\BIN in the system and

user variables (Start à My Computer à Control Panel à System à Advanced and then in

the "Environment" tab).

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage6of32

TI-430 Andreas Schandl Release date: 29.09.2006

1.8 EDIABAS error: Error (95) SYS-0005: OBJECT FILE NOT FOUND

Reason 1: No SGBD in C:\EDIABAS\ECU

Solution 1: Copy the SGBD into the Ecu directory.

Reason 2: No group file in C:\EDIABAS\ECU (for group call)

Solution 2: Copy the group file to C:\EDIABAS\ECU

Reason 3: No path definition C:\EDIABAS\BIN

Solution 3: Set the system variable (see 2.1)

Reason 4: Incorrect path definition in EDIABAS.INI

Solution 4: Set the EcuPath path in Ediabas.ini to C:\EDIABAS\ECU

Reason 5: The SGBD name contains reserved characters or is too long. Only 8 characters

are allowed (a-z, A-Z, 0-9, "_").

1.9 Createfile_error: OPEN CONNECTION; IFH 0018- INITIALIZATION

ERROR

ADS Interface:

The following error appears when Ediabas is started:Createfile_error: OPEN

CONNECTION

OBD Interface:

The following error appears when Ediabas is started:Error 28: IFH 0018- INITIALIZATION

ERROR. (Also see Section 3.3)

Reason: Ediabas is attempting to access port COM1. However, the port doesn't exist, or it

has been taken by anotherprogramme(e.g. HotSync from Palm, infrared).

Solution: Install a COM1 interface or free it.

1.10 Battery and Ignition notrecognised

Reason: With a Dell Latitude D600 laptop, pin 9 has no function and it is therefore not

able to correctlyrecognisethe battery status.

Solution 1: Use OBD via USB, see C:\EDIABAS\BIN\INI.PDF Chapter 2.2 for this.

Solution 2: The laptop is connected to the docking station.

Solution 3: Workaround for the OBD driver as of February 2004: A file "OBD.ini” must be

created in the directory C:\WINDOWS for Windows XP, or alternatively

C:\WINNT for Windows NT, with the following entry. This is because with

UBATT=OFF, the battery status is not determined via hardware, but is

permanently set to "Battery voltage available”.Alsosee OBD_DOKU.pdf in the

\Ediabas\Hardware\OBD directory.

Entry in OBD.ini:

[OBD]

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage7of32

TI-430 Andreas Schandl Release date: 29.09.2006

UBATT=OFF

1.11 Warning when starting OBD Setup

A warning occurs when starting C:\EDIABAS\HARDWARE\OBD\OBDSetup.exe. After You

want to start Tool Set or INPA You will get the following error message:

Reason: The value of the variable DWORD (here RxFIFO) can not be set by

OBDSetup.exe.

Solution: You have to set the value of theDWORTin the registry. You have to open the

Regedit by using Start à Ausführen… à enterregedità OK. Choose the

following path in theregedit: HKEY_LOCAL_MACHINE à System à

CurrentControlSet àclickon Services. On the right side of thewindowYou can

cklickon the name of the DWORd value which is defective (here RxFIFO). Enter

the value 8 with the base hexadecimal. Click Okanclose theregedit. Now You

can start the Tool Set or INPA without an error.

If You have warnings for other DWORDs whenstartigOBDSetup.exe, You will

have to set the value of thecoloum„Expected" for the wrong value in the registry.

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage8of32

TI-430 Andreas Schandl Release date: 29.09.2006

1.12 ERROR C1015: Too Many String Variables in Job

Reason: In a job only a maximum of 6 string-variables is acceptable.

Solution: You have to reduce the number of variables.

1.13 Failure: EDIABAS Fehler 159, NET-0009: TIMEOUT

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage9of32

TI-430 Andreas Schandl Release date: 29.09.2006

Reason 1: The configuration for theremotehostis false.

Solution 1: Set the correspondingnetworknamefor theremotehostin the configuration file

EDIABAS.INI.

Reason 2: Theinface-cable on the OPPS is not correct.

Solution 2: You need a special OPPS-Cable for the connection with the CAN-BUS. (since

type series L6)

Reason 3: In theremotecontrolthe OPPS-interface is used by default (since EDIABAS 7.0).

Theremotecontrolbetween two PC’s is not possible with this configuration.

Solution 3: Close alldiagnosticapplicationsand EDIABAS-Processes that are running and

open the file "remote_mit_pc.bat” in the directory C:\EDIABAS\bin.

1.14 Failure: The name of the file or folder can t be changed

Reason: EDIABAS or another component of EDIABAS is still open.

Solution: You have to shut down thediagnosticapplicationand EDIABAS. If necessary, the

fileexplorerand the editors which access the EDIABAS-Directory have to close

as well.

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage10of32

TI-430 Andreas Schandl Release date: 29.09.2006




2.1 APLDLL or API32.DLL can’t be found.

When calling INPA under Windows NT, the following error messages appear:

Reason 1: The path C:\EDIABAS\BIN has not been set in the ‘Path’ system variable.

Solutionwith Windows NT:

Set the system variable: Please log into your system as the administrator with administrator

rights. Use Start à My Computer à Control Panel to call the "System” menu. In the

"Environment” tab, double click the system variable ‘Path’.

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage11of32

TI-430 Andreas Schandl Release date: 29.09.2006

Go to the end of the field value. There, enter a semicolon and then enter the path

C:\EDIABAS\BIN. Click "Set” and "OK”.

Solutionwith Windows XP:

Set the system variable: Please log into your system as the administrator with administrator

rights. Use Start à Control Panel to call the "System” menu. Under "Advanced” and the

"Environment” tab, double click the system variable ‘Path’.

Go to the end of the variables field value. There, enter a semicolon and then enter the path

C:\EDIABAS\BIN.

Click "OK”.

Completely restart your computer!!! (Don’tloginunder a new name or the like.) It should no

longer be a problem to call INPA.

Reason 2: Ediabas is not installed, only INPA is.

Solution 2: Install Ediabas.

When calling INPA under Windows 95, 98, the following error message appears:

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage12of32

TI-430 Andreas Schandl Release date: 29.09.2006

Reason: The path C:\EDIABAS\BIN has not been set in the ‘Path’ system variable.

Solution: Set the system variable:

Open the file Autoexec.bat in the directory C:\ by clicking it with the right mouse key with the

shift key pressed, and then select "Open with”. The best thing is to use the Notepad to

display the file.

Now, at "path”, enter the path c:\ediabas\bin.

Save the change and close the file.

Completely restart your computer!!! (Don’tloginunder a new name or the like.)

2.2 Error Message 0020: Incorrect or Missing Driver. Theprogrammewill

be aborted!

Conditions:

You have access to \\smuc0900\sg. You are linked to this drive and would like to start an

INPA script.

Reason 1: Missing Ediabas.inifile in C:\Winnt.

Reason 2: You are not connected to the controller.

For developers: Simulation is not switched on in the Ediabas.inifile.

Solution: Copy the Ediabas.inifile from C:\Ediabas\Bin to C:\Winnt.

2.3 SYS-00002: ECU variation description file not found.

The error occurs when starting an INPA script.

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage13of32

TI-430 Andreas Schandl Release date: 29.09.2006

Reason 1: The *.prg SGBD is not located in the path C:\Ediabas\Ecu.

Solution 1: Copy the *.prg SGBD into the ECU directory.

Reason 2: The external table T_GRTB.prgdoesn’t exist in the directory C:\EDIABAS\ECU

or it is obsolete.

Solution 2: Copy the file into the ECU directory or update the external table using the ECCO

Web Client.

2.4 INPA Error: Error at CompilingàAbort!

The following error message appears when starting an INPA script.

Reason 1: An INPA script with the ending IPO was started by theprogrammeINPA.EXE

instead of by theprogrammeINPALOAD.EXE.

Solution 1: Only start INPA scripts that end with IPO withINPALOAD.EXE.

Reason 2: The selected INPA script doesn’t exist in the C:\INPA\SGDAT\ directory.

Solution 2: Update the INPA scripts using the ECCO Web Client.

Reason 3: INPA Version 5.0.1: The INPA script *.IPO can’t be started with a double-click in

the directory C:\INPA\SGDAT\*.IPO.

Solution 3: Update to Version 5.0.2.

Reason 4: INPA Version 5.0.1: The desktop link of an INPA script doesn’t work.

Solution 4: The target path must be expanded to include the INPALOAD path. To do this,

click the desktop link once with the right mouse button and go to ‘Properties’.

Expand the target path to include C:\INPA\BIN\INPALOAD.exe for Windows NT

(see Fig.) and C:\EC-Apps\INPA\BIN\INPALOAD.exe for Windows XP.

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage14of32

TI-430 Andreas Schandl Release date: 29.09.2006

Grund 5: The file startger.ipo of thegermaninstallation and the filestartus.ipo of the

englishinstallationdon’texist in the directory \INPA\CFGDAT\.

Lösung 5: Install INPA once again.

2.5 IFH-0018:InizialisationError – INPA doesn’t work but Toolset yet

The error occurs ifa SGBDis running by INPA or CASCADE. If the same SGBD is loaded in

the Toolset it will notoccureaninizialisationerror.

Reason 1: The communications port COM1 doesn’ exist, but COM3 yet. The Toolset is

working without theinizialisationerror,because the file OBD.ini exists in the

directory C:\Ediabas\bin\. But the file OBD.ini has to exist in thedirecory

C:\Windows.

Solution 1: Copy the file OBD.ini in the directory C:\Windows or create a new one. (Creation

of OBD.ini q.v. 3.3).

Grund 2: q.v. 3.3

Lösung 2: q.v. 3.3

2.6 IFH-0027: IFH not foundàThe Programm was aborted!

The error occurs when starting INPA.

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage15of32

TI-430 Andreas Schandl Release date: 29.09.2006

Reason 1: The setting for the interface in the configuration file Ediabas.inidoesn’t exist.

Solution 1: Please do the settings for the interface e.g.:

Interface = STD:OBD

Reason 2: The setting for the interface in the configuration file Ediabas.ini is

Interface=STD:OMITEC, but the OMITEC driver isn’t installed correctly.

Solution 2: Install the OMITEC driver with the instructions

InstructionforOMITECInstallation.pdf via the GIS server.

Reason 3: The setting for the interface in the configuration file Ediabas.ini is

Interface=OMITEC, but the correct setting isInterface=STD:OMITEC.

Solution 3: Please do the settings for the interfaceInterface=STD:OMITEC.

Reason 4: The old OMITEC driver wasn’t uninstalled correctly.

Solution 4: Please uninstall the old OMITEC driver with the instructions

InstructionforOMITECInstallation.pdf via the GIS server.

2.7 INPA Error: Opening Inpa – Transmission error returned a_0x2

Reason: During the installation of Ediabas/Inpa, the configuration "Without configuration”

was selected.

Solution: When running the installationprogramme, select a configuration, e.g. "BMW

Plant 1.1 Munich”.

2.8 INPA Error: Only a white screen appears when you run INPALOAD.EXE.

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage16of32

TI-430 Andreas Schandl Release date: 29.09.2006

Reason 1: The api.dll or api32.dll file has been manually copied into the WINDOWS

directory with Windows XP and into the WINNT directory with Windows NT.

Solution 1: Delete the file api.dll or alternatively api32.dll from the WINDOWS or alternatively

the WINNT directory. The file may only exist in the directory \EDIBAS\BIN\.

Reason 2: You have installed the 32-bit version of INPA (as of Version 5.0.1) and have not

performed an update of the INPA scripts.

Solution 2: Update the INPA scripts using the ECCO Web Client.

2.9 INPA Error: DTM is no longer supported

Reason: This error message appears if INPA.INIhas been copied from Version 4.7.7 to

Version 5.x.x.

Solution: Since it can’t be excluded that even more files from the old version have been

mixed with the new ones, the old ones must be deleted, or alternatively

reinstalled (see Chapter 5). Reinstall INPA using the Global Information Service

(GIS) https://gis.bmw.com.

2.10 INPA Error: Bridge16.exe can’t beinitialised

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage17of32

TI-430 Andreas Schandl Release date: 29.09.2006

Reason 1: A 16-bit INPA script has been started with the 32-bit version of INPA (as

of Version 5.0.1).

Solution 1a): Update the INPA scripts using the ECCO Web Client.

Solution 1b): Convert the INPA script to the standard ‘includes’ for the 32-bit version.

To do this, contact the respective person responsible for INPA at TI-43x

(see \\smuc0900\sgref\Referenz\Referenz.inp)

Reason 2: A 16-bit DLL has been found, which means the developer of the INPA

scriptis using a 16-bit DLL.

Solution 2: The developer of the INPA script must convert the DLL to 32-bit.

2.11 Error when opening the error fileàabort:

Reason: This error occurs with Windows XP because the user doesn’t have the correct

rights to change files in the directory C:\INPA\Bin.

Solution: The user needs "Power user” rights or the user needs the appropriate write rights

to the "INPA” directory.

2.12 Compiler: File: \INPA\DEUTSCH\***.OUT not found!

Reason: The path C:\EDIABAS\BIN has not been set in the ‘Path’ system variable.

Solution: Set the path C:\EDIABAS\BIN in the ‘Path’ system variable. (q.v. chapter 2.1).

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage18of32

TI-430 Andreas Schandl Release date: 29.09.2006




3.1 EDIABAS error 100: SYS-0010: INITIALIZATION ERROR

Reason: This message comes when an SGBD has an automatic concept switch between

multiple diagnostics logs and is not connected to the controller.

Solution: Connect the controller.

3.2 EDIABAS Error 126 (only up to Ediabas V6.4.x)

Reason: This error message appears if you start the Tool Set while an INPA script is

running. This is also true the other way round. The reason for this is that only one

programmecan access EDIABAS at a time.

Solution: Therefore, before you start the ToolSet, you must exit INPA!!!

3.3 IFH-0006: Command not accepted and IFH-0018: Initialization Error and

IFH-0038: Interface Command not implemented

Errors IFH-0006 and IFH-0018 occur if any SGBD is loaded in the Tool Set. Error IFH-0038

is generated when loading the utility file into the Tool Set.

Reason 1: The error was caused by anotherprogrammethat accessed the COM1

interface. Thisprogrammecould be "HotSync” for Palm or "ActiveSync”

forlpack.

Solution 1: Check theprogrammesthat are started automatically when Windows is

started (see Chapter 4.1).

Reason 2: The COM1 interface is taken by a serial printer.

Solution 2: Uninstall the printer.

Reason 3: The infrared interface is active.

Solution 3: Deactivate the infrared interface.

Reason 4: There is no COM1 interface (COM3 instead, for example)

Solution 4a): Install the COM1 interface.

Solution 4b): Create a file with the name OBD.ini and make the following entry to set

the existing serial interface (COM3, for example):

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage19of32

TI-430 Andreas Schandl Release date: 29.09.2006

[OBD]

Port = Com3

The file OBD.ini must be saved in the directory C:\WINDOWS\ for

Windows XP or in directory C:\WINNT\ for Windows NT up to the Ediabas

Package 1.3 and as of Ediabas Package 1.4 in directory

C:\EDIABAS\BIN\. The current version of the Ediabas Package can be

seen in the files C:\EDIABAS\version.txt or C:\EDIABAS\package.pdf.

Reason 5: Only for IBM notebooks: The COM1 interface is reserved for the docking

station; the COM3 interface is installed instead.

Solution 5a): see solution 4b:

Solution 5b): Set the COM3 port to COM1: In the device manager (Windows XP:

Select "Start” à "Control Panel” à "System” à "Hardware” and then

select COM3 from the ports under the menu item "Device Manager”.

Then use the right mouse button à "Properties” à "Port Settings” à

"Advanced” to reach the "Advanced Settings for COM3”. Set COM1 in the

COM Port Number. The message that COM1 is already taken can be

ignored in this case.

Reason 6: The old OMITEC driver wasn’t uninstalled correctly.

Solution 6: Please uninstall the old OMITEC driver with the instructions

InstructionforOMITECInstallation.pdfvia the GIS server.

3.4 IFH-0006: Command not accepted

This error occurs ifa SGBDis loaded in the Tool Set when the OBD connector is being used.

Reason 1: ODB has actually been set as the interface in Ediabas.ini, but the Tool Set uses

the multi-instance with another interface, e.g. K-Line. The setting for themultiinstance

and the interfaces used here is made in the file Tool32.ini in the

directory C:\Windows (for Windows XP) or alternatively C:\Winnt (for Windows

NT). Then, the entries in Tool32.ini, or alternatively the interface apply and not

the ones in Ediabas.ini. The use of multi-instance in the Tool Set is identified in

the title bar, for example with "Tool32:1”, for single multi-instance.

Solution 2: Enter the interface that is being used in Tool32.ini ordisablemulti-instance with

the entry "No”.

Reason 2:A SGBDis loaded in the Tool Set when the diagnosis protocol UDS is being

used. For UDS-SGBDs You have to use the interface OMITEC but in the

EDIABAS.ini the setting fort heinterfaceist„STD:OBD".

Solution 2: Change the setting forthrinterface to „interface =STD:OMITEC" in the

EDIABAS.ini file. The OMITEC connector has to be stressed by the voltage (blue

blinking). If the connector can’t be stressed by the voltage and You want to load

the SGBD yet, You will use the simulation mode. You can activate the simulation

mode e.g. with themenue„configuration -> EDIABAS". Notice, if you want to use

the simulation mode, a simulation file for the interface will have to exist in the

simulation path.

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage20of32

TI-430 Andreas Schandl Release date: 29.09.2006

3.5 IFH-0009: ECU isn’t connected or doesn’t respond

Reason 1: In the Ediabas.inifile, the interface is set toSTD:ADS. However, you have

connected an OBD connector.

Solution 1: Modify the interface setting.

Reason 2: The ignition is switched off.

Solution 2: Switch the ignition on.

Reason 3: The device manager has been used to disable the FIFO buffer for COM1.

Solution 3: In the device manager (Windows XP: Enter "Start” à "Control Panel” à

"System” à "Hardware” à "Device Manager” à Ports (COM & LPT)), and select

COM1 from the ports and under the "Port Settings” tab, select "Advanced”. There

must be a check-mark by "Use FIFO buffers” and the highest possible setting

must be selected for the receive buffer.

3.6 SYS-0002: ECU OBJECT FILE NOT FOUND

Reason 1: If the external table T_GRTB.prgdoesn’t exist in the directory C:\EDIABAS\ECU\

the error message will be displayed when You execute the job

IDENT_FUNKTIONAL of a functional SGBD.

Solution 1: You have to download the external table using the ECCO Web Export and copy it

in the directory C:\EDIABAS\ECU\.

Reason 2: The SGBD, which You want to start doesn’t exist in the directory

C:\EDIABAS\ECU or is an old one.

Solution 2: You have to download the SGBD using the ECCO Web Client and copy it in the

directory C:\EDIABAS\ECU\.

3.7 SYS-0005: Controller description file not found. Theprogrammewill be

aborted!

Reason 1: The SGBD is not located in the path C:\Ediabas\Ecu.

Solution 1: Copy the SGBD into the Ecu directory.

Reason 2: This error occurs if the EcuPath in Ediabas.ini(C:\Ediabas\Bin) isn’t set to

C:\EDIABAS\ECU.

Solution 2: Set the correct path.

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage21of32

TI-430 Andreas Schandl Release date: 29.09.2006

3.8 ToolSet Error: Runtime error ’372’

The following error message appears.

Reason: The old version msflxgrd.ocx exists under c:\winnt\system32.

Solution:msflxgrd.ocx under c:\Ediabas\bin must be registered. To do this, select "Start”

à "Run…” and executeregsvr32 :\ediabas\bin\msflxgrd.ocx in the window and

confirm with "OK".

The following must be entered for Windows XP: "regsvr32 c:\ediabas\bin\

msflxgrd.ocx"

3.9 Tool Set Error: Run-time error ’5’ – Invalid Procedure Call

Reason: The Tool Set was started twice in a very short period of time.

Solution: Close all Tool Set processes that are running and start the Tool Set again with

only one double-click.

3.10 Tool Set Problem: If an SGBD is opened, then only the hourglass

appears and the SGBD is not loaded.

Reason: An old version Richtx32.ocx exists under c:\winnt\system32.

Solution: Richtx32.ocx under c:\Ediabas\bin must be registered. To do this, select "Start”

à "Run…” and execute "regsvr32 :\ediabas\bin\richtx32.ocx" in the window and

confirm with „OK".

The following must be entered for Windows XP: „regsvr32 c:\ediabas\bin\

richtx32.ocx"

3.11 EDIABAS error 20: IFH-0010: Data transmission to control unit

disturbed

Reason 1: When using the EDIC card, the error message is issued when executing the

IDENT job.

Solution 1: Changes must be made in the file "XEDICC.ini” in the "...\Ediabas\Bin" directory.

There, the parameters set for high-speed must be commented out and the

parameters for low-speed must be enabled:

;highspeed:

;Interface=1;

;Presc=0x01;

;SJW=0x01;

;TSEG1=0x08;

;TSEG2=0x07;

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage22of32

TI-430 Andreas Schandl Release date: 29.09.2006

;lowspeed:

Interface=2;

Presc=0x0A;

SJW=0x02;

TSEG1=0x05;

TSEG2=0x02;

Reason 2:A SGBDis loaded in the Tool Set when the diagnosis protocol UDS is being

used. You use the interface OMITEC but the connector isn’t stressed by the

voltage (no blue blinking).

Solution 2: Connect the OMITECwitthe vehicle. The OMITEC connector has to be stressed

by the voltage (blue blinking). If the connector can’t be stressed by the voltage

and You want to load the SGBD yet, You will use the simulation mode. You can

activate the simulation mode e.g. with themenue„configuration -> EDIABAS".

Notice, if you want to use the simulation mode, a simulation file for the interface

will have to exist in the simulation path.

3.12 EDIABAS Error 134: API-0014: Result not found

The error occurs ifa SGBDis loaded in the Tool Set when the diagnosis protocol UDS is

being used and the Job FS_LESEN is being executed.

Reason: You use the setting "read error like INPA”, but the Toolset can’t support the

function yet for UDS-SGBDs.

Solution: Please remove the setting "read error like INPA” in themenue"configuration ->

Toolset”.

3.13 It takes too long to load an SGBD in the Tool Set

Loading motor or transmission SGBDs takes an above average amount of time.

Reason: Large SGBDs often contain many and extensive tables and their information has

to be loaded.

Solution: Under the Configuration menu item in the Tool Set and then Tool Set, the

checkmarkby the selection of table information must be removed.

3.14 Black Windows in the Tool Set

After loadinga SGBDone or more windows of the Tool Set are black windows.

Reason: The registration of therichtextboxis invalid.

Solution: You have to register therichtextbox. Execute the batch file REGSVR32.BAT in

the directory C:\Ediabas\bin\.

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage23of32

TI-430 Andreas Schandl Release date: 29.09.2006




4.1 Installation of EDIABAS and INPA

The Installation of EDIABA,INPAand NFS have to be donewebbasedvia the Global

Information Service (GIS). You can reach the GIS homepage with the following link:

https://gis.bmw.com/.

In the forum „BMW Standard Tools Werk" You can find the installation data of EDIABAS,

INPA and NFS. The pathistshownbelow:

BMWStandardToolsWerk

Standard Tools/ Tool InstallationWerk

EDIABAS

INPA

NFS

Foraccesrights for the GIS forum „BMW Standard Tool Werk" sendanmailto

Referenz@bmw.de stating the name the Q/QX numberan thereason. We can give access

rights for this forum only for colleagues from the Tdepartements. Colleagues from other

departments andsupplierescan get the installation via the GIS forum „BMW Standard Tools

Entwicklung". You can apply for access rights using the following link:

https://gis.bmw.com/gis/d/toolsantrag.htm.

Please pay attention to theintallationinstructions which You can get in the same directories

of the installation data. After theintallationYou have to download the SGBDs, INPA scripts,

Group SGBDs, INPA configuration files and external tables using the ECCO Web Client.

Which data You have to download is described in the following chapter 4.2.

4.2xBD-Export of SGBDs, Group SGBDs, INPA scripts and INPA

configuration files using the ECCO Web Client

The update of SGBDs, group SGBDs, external tables, INPA scripts and INPA configuration

files can be donewebbasedusing the ECCO Web Client.

You can apply foraccesrigthsfor ECCO at the user service center (Tel. 089-382-55555)

stating Your valid Q/QT/QX number.

You can reach the homepage of the ECCO Web Clients with the following link:

http://www6.muc/ppea. AfterloginYou have to select the linkxBDExport in the navigation

bar and You can see the search screen. You have the possibility to search for a single file or

search for all files assigned to a certain typeserieor search fora several release periods.

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage24of32

TI-430 Andreas Schandl Release date: 29.09.2006

If You have installed EDIABAS You will need following files:

  • SGBD_Revisionen
  • GRP_SGBD_Revisionen
  • ExterneTabelle_Revisionen

If You have installed INPA You will need following files:

  • SGBD_Revisionen
  • GRP_SGBD_Revisionen
  • ExterneTabelle_Revisionen
  • Inpa_Script_Revisionen

In the column „Verfügbare Dateitypen" You have to select the data types.These columnis

very importantvorthe export of the files, i.e. the data types which are selected will be

exported. Please payattentiononthe correct selection.

If You have installed EDIABAS You will select the following data types:

  • SGBDprg_english or SGBDprg_deutsch
  • SGBDgrp
  • EXTABprg_english or EXTABprg_deutsch

If You have installed INPA You will select the following data types in addition to the data

types above:

  • INPAipo_english or INPAipo_deutsch

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage25of32

TI-430 Andreas Schandl Release date: 29.09.2006

  • Select also „Benutzereinst.verwenden"
  • Select also „INPA-Konf.-Dateien"

After the download of the necessary files You have to copy the files in the right directories:

EDIABAS data:

1 …\EDIABAS\ECU\

  • SGBDen: SGBDprg_deutschàalle*.prg-Dateien
  • externe Tabellen: EXTABprg_deutschà T_GRTB.prg, T_PCOD.prg
  • Gruppen-SGBDen: SGBDgrp_deutschàalle*.grp-Dateien

INPA data:

1 …\INPA\SGDAT\

  • INPA scripts: INPAipo_englishà all *.ipo files

1 …\INPA\CFGDAT\

  • INPA-Konfig-Files: INPA_Konfig_xBD_Download_eng.zip

à all *.ger files or *.eng files

Inpa.ini file

ger =germanINPA config, eng =englishINPA config

If You have problems with thexBDExport using ECCO Web Client please call the user

service center: Tel. 089-382-55555 or send a mail to ECCO hotline: ecco.hotline@bmw.de.

4.3 How can I find out if the serial interface COM1 has been taken?

There is a way to find out if the serial interface, forexampleCOM1, has been taken, but it is

not possible to find out whatprogrammehas taken the interface.

As described in the respective sections of Chapter 3, theprogrammesthat most often take

COM1 are HotSync for the Palm and ActiveSync for thelpackor a Nokia software. In order

to establish whether theseprogrammesare automatically started when you start the

computer, please check your ‘Autostart’ settings. Do this by making sure that these

programmesdon’t appear in the following directories:

- C:\Documents and Settings\All Users\Startmenu\Programs\Autostart\

- C:\Documents and Settings\Your QX Number\Startmenu\Programs\Autostart\

Another way to check theutilisationof COM1 is to look in the system information. The

system information can be run with the DOS commandwinmsdin an input prompt (Start à

Run… à enterwinmsdà OK). Here, it is important that you only runwinmsdif the Ediabas

server is closed. Under the path System Summary à Components à Ports à Serial, the

information about the active serial ports COM1, COM2, and so on will be shown if they exist.

The current value can be seen in the element "Busy”. If this value is "No”, then the interface

is free, and if it is "Yes”, then the interface has been taken by aprogramme. You can’t find

out whatprogrammeit is here.

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage26of32

TI-430 Andreas Schandl Release date: 29.09.2006

4.4 How do I start INPA?

Start Inpa using Inpaload.exe in C:\Inpa\Bin or alternatively C:\EC-Apps\Inpa\Bin or use

Start à All Programs à EDIABAS INPA ELDI NCS NFS à INPA(_.IPO) to start the general

reworkingprogramme. This corresponds to calling Inpaload.exe under

smuc0900\sg\Inpa\Bin or alternatively C:\Inpa\Bin.

4.5 How can I switch between OBD and ADS interfaces?

Prerequisite:

The appropriate driver must be installed for the interface that you want to use. In the

installation guide for INPA (http://smuc0900/TI-430 or http://smuc0900/TI-430 under Subjects à

EDIABAS /INPA à EDIABAS or INPA), you can look up how a driver is installed.

Now, you can change the interface directly in the fileEdiabas.ini(C:\EDIABAS\BIN). You

only have to make the appropriate change to the line where the interface is entered.

Interface =STD:OBD, i.e the OBD interface will be used.

Interface = ADS, i.e the ADS interface will be used.

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage27of32

TI-430 Andreas Schandl Release date: 29.09.2006

For the case that OBD is being used via USB, an additional entry isnecessary inOBD.ini.

See C:\EDIABAS\BIN\INI.PDF for this.

4.6 In which directory structure is OBD.ini saved?

If the OBD.ini file exists, then in order to not run the interface via COM1 by default (compare

to 1 i), then the OBD.ini file must be saved in the directory C:\WINDOWS\ for Windows XP

or in directory C:\WINNT\ for Windows NT up to the Ediabas Package 1.3 and as of Ediabas

Package 1.4 in directory C:\EDIABAS\BIN\. The current version of the Ediabas Package can

be seen in the files C:\EDIABAS\version.txt or C:\EDIABAS\package.pdf.

4.7 How can I find out what interface I installed with INPA?

To do this, you have 2 possibilities:

  1. Call Start à All Programs à EDIABAS INPA ELDI NCS NFS à EDIABAS Tool32. In

the configuration menu, select Ediabas. There, you will find the desired information in the

interface line.

  1. However, you can also check in theEdiabas.ini(C:\EDIABAS\BIN) to see what

interface you have installed. For the OBD interface, you will find the line ‘Interface =

STD:OBD’and for the ADS Interface the line ’Interface = ADS’.

4.8 How do I find out what EDIABAS package is installed?

The version of the currently installed Ediabas package can be seen in the files

C:\EDIABAS\version.txt or C:\EDIABAS\package.pdf.

4.9 How can I uninstall EDIABAS or INPA?

You uninstall INPA by deleting the Ediabas and Inpa folders under C:\.

Reason: No registry entries are made during the installation.

4.10 How can tell if the EDIABAS server is running as a 16-bit or a 32-bit

application?

Under Windows 95 and 98, the EDIABAS server runs as a 16-bit version.Thecan be

recognisedby the yellowEin the task bar.

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage28of32

TI-430 Andreas Schandl Release date: 29.09.2006

Under Windows NT4 and XP, the EDIABAS server runs as a 32-bit version. This can be

recognisedby the greenEin the task bar.

Note:

As of 2003, there is the EDIABAS Version 6.4. This can also run as a 32-bit application

under Windows 95/98 and XP.

4.11 What is the difference between \EDIABAS\bin\ToolSet.exe and

\EDIABA\bin\Tool32.exe?

Tool32.exe is current and when it is started, the Ediabas server will start as a 32-bit

application. ToolSet.exe is an old version and is required under Windows 3.11.

4.12 What is an SGBD and what is its connection to EDIABAS?

The controller description files (SGBD) contain the controller-specific know-how. Each SGBD

contains the order telegram of the respective controller and decodes its reply telegrams. In

the process, the raw data (bytes) is converted into directlyuseablevariables (Data types: int,

long, real, string), i.e the error code is converted into error text.

For each controller variation, there is exactly one variation-specific SGBD.

The SGBDs are loaded and interpreted by the EDIABAS runtime system by an application

programmewhen the order is issued. The file name of the SGBD (without extension) is the

name with which the applicationprogrammeaddresses a controller variation or controller

group.

4.13 Where are the individual SGBD names and theirmeanings givenin

plain English?

Click the "Show” Version List SGBD button on the ”Dienste Tool” interface. There will be a

list of all SGBDs by name with the current version number, the person responsible at BMW,

and the name of the associated controller. It is only possible to access the version list when

the network is in operation or it can be viewed at \\smuc0900\Referenz\Referenz.sgbd.

4.14 What is a Job?

Jobs are services that EDIABAS provides. They aren't hard coded inEDIABAS,but are a

maincomponent of each SGBD.

Each job has a fixed name and any number of results. Jobs are independent of each other.

There is no data exchange between jobs.

A job corresponds to a function with one complete order. It usually reads data from a

controller,analysesit and returns results that can be used directly by different applications.

A job normally works with one diagnostics telegram (multiple in exceptional cases).

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage29of32

TI-430 Andreas Schandl Release date: 29.09.2006

4.15 What do SGBDs with the name _xxx mean?

SGBDs that begin with "_” (e.g. _LWS5), contain jobs that are only intended for development

(e.g.: writing the ident data). These SGBDs are not used in production or in customer service.

4.16 What is the group file used for?

Among other things, INPA uses group files to select the respective SGBD. The group

identifies the controller and starts the corresponding SGBD. The choice is made using the

diagnostics, and as of E65 using the variation index in addition.

The group files are located in C:\EDIABAS\ECU and have the following naming convention:

D_00xx.grp were assigned up to the E65; xx = the controller address; For example:

D_0032.grp = transmission. The name D_??????.grp is assigned after the E65 and is

legible; for example D_KLIMA.grp or D_MOTOR.grp, etc.

Updating the group files as of the E65 has changed since February 2004. The table with the

information about which controller must load which SGBD, depending on the diagnostics and

variation index, was moved from the group file to an external table. At runtime, theswappedout

table C:\ECU\T_GRTB.prg is used. Therefore, it is now only necessary to update this

table and not D_??????.prg.

Additional Information for SGBD Developers:

In the file STD_GRTB.b2s, the diagnostics andvariationindexes of the individual SGBDs

can be seen as well as the group file to which the respective SGBD is assigned. You can

find the file STD_GRTB.b2s on drive \smuc0900\sg\ in directory \Referenz\Ediabas\Include\.

4.17 Diagnostics Index

  1. a) Who creates it? Reinhold Drexel, TI-430
  2. b) What is it used for? Identification of the controller
  3. c) When does it change? When a new SGBD is due

4.18 Variation Index

  1. a) Who creates it? Data handling team
  2. b) What is it used for? Identification of the ECU
  3. c) When does it change? When the SGBD and/or the PABD changes (PABD, if

something in ECU programming changes), e.g. if the

authentication changes or a timing has changed).

4.19 What is the meaning of the file EDIABAS.ini?

Ediabas.ini is the configuration file. Normally, no changes must be made here after the

installation. One reason for a change to Ediabas.ini is, for example, if you want to work with

a simulation file, i.e. there doesn’t have to bea ECU.

The Ediabas.ini can be found in the \Ediasbas\Bin directory.

EcuPath:

The group files (d_*.grp) and SGBDs (*.prg) are found in the path given for EcuPath. In the

developer versions, it also contains *.b2v, *.b2s and *.txt files.

SimulationPath:

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage30of32

TI-430 Andreas Schandl Release date: 29.09.2006

The path given in the SimulationPath is where the simulation files are located for groups

(d_*.sim) and for SGBDs (*.sim), whichareonly relevant to SGBD and INPA developers.

TracePath:

If ApiTrace and/orlfhTraceare activated, then the traces will be stored there with api.trc and

ifh.trc.

TraceSize:

You can set the size of the trace files ApiTrace and IfhTrace. If 1024 is set, then the

maximum size of the file is 1 MB; for 512, it is a maximum of 500 KB.

ApiTrace:

The ApiTrace file is activated by replacing the zero with a number from 1 to 7. The api.trc file

contains the job and result names with their data. If ApiTrace is not needed, this should be

set to zero to increase the performance of EDIABAS. You can find information about the

trace level in the Ediabas documentation.

IfhTrace:

ThelfhTracefile is activated by replacing the zero with a number from 1 to 3. The ifh.trc file

only consists of the telegrams that have been sent (INPUT) and received (OUTPUT). If

lfhTraceis not needed, this should be set to zero to increase the performance of EDIABAS.

Simulation:

Simulation is used to check the SGBDs and INPA scripts without being directly connected to

a ECU. This function is activated by changing the zero to 1.

Interface:

You can directly change the interface here. You only have to make the appropriate change

to the line where the interface is entered.

Example:

Interface =STD:OBD, i.e the OBD interface will be used.

Interface = ADS, i.e the ADS interface will be used.

The prerequisite is to have the appropriate driver installed for the interface.

Excerptformthe Ediabas.inifile:

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage31of32

TI-430 Andreas Schandl Release date: 29.09.2006

4.20 How is the simulation file connected to the trace file?

There is one simulation file for each ECU. In this file are the ECU’s request and reply

telegrams. This file has the same name as the ECU description file,howeverit has the

ending "*.SIM” (e.g. DME31.SIM).

There is also a separate simulation file for each interface that is to be simulated. The

filename is made up of the name of the interface with the ending "*.SIM” (e.g. EDIC.SIM).

The setting of the EDIABAS configuration element calledInterfacewill be used as the

interface name. The interface-specific return values are in the interface simulation files.

The trace file records the telegrams that have been sent (INPUT) and received (OUTPUT).

The recording of such traces can be enabled in the Tool Set in the menu bar under

"Configuration” as well as in the Ediabas.iniconfiguration file.

A simulation file can be automatically created from the ifh.trc trace file by using

trace2sim.exe. This tool is found in \\smuc0900\sg\Ediabas\Sim\ trace2sim.exe.

4.21 Why have an XBD Generator?

Before the introduction of the SGBD generator, the source code was edited with a text editor

(up to 40,000 lines). For this purpose, it was necessary to learn the special, C-based

programming language BEST/2 (description language for ECU). Manual programming is

known to be very prone to errors (copy & paste), and it is very difficult to implement the

guidelines specified in the diagnostics specification sheet part 5 as the SGBD becomes

larger.

Now, the SGBD Generator is to be used to create an SGBD by means of menu-driven input

of the data, in which the BMW guidelines are kept. This should result in less effort for the

developer, but it definitely requires a certain amount of practice in working with the SGBD

Generator. A major advantage is the automatic integration of standard ‘include’ files,

whereby new standard ‘includes’ can be added without further ado (new sample XML).

4.22 What are the prerequisites for remote access via TCP/IP?

EDIABAS for WIN32 makes it possible to access the diagnostics interfaces and the attached

ECUs that are connected to another PC. The prerequisite for this is a network connection of

locally and remotely controlled PCs via TCP/IP as well as a WIN32 operating system that is

supported by EDIABAS.

Applications and EDIABAS run on the local PC and the interface handler (IFH) as well as the

IFH-Serverrunon the PC to be remotely controlled. Before accessing the remotely

controlled PC, the IFH server IFHSRV32.EXE must be started. The remote control is

activated,or alternatively controlled using the EDIABAS configuration file EDIABAS.INI. The

EDIABAS configuration must be performed manually on both PCs.

The EDIABAS configurationsTracePathandSimulationPathare not transferred from the

local PC to the remotely controlled PC, rather the respective configurations of the

EDIABAS.INIfile that is on the remotely controlled PC is used.

The network protocol TCP (NetworkProtocolentry) as well as a freely selectable port

number must be given on both PCs. The port number must be identical on both PC and

must not collide with other TCP applications (1000 < port number < 30000).

Frequently Asked Questions

BMW Group about

EDIABAS, INPA and the Tool SetPage32of32

TI-430 Andreas Schandl Release date: 29.09.2006

4.23 What is the VC Tool and when is it used?

VC Tool (version check) can be used to check the versions of the files that are created

during the installation of EDIABAS. When it runs, the tool compares the files specified in the

files BMW_bin.pid,BMW_hw.pidand BMW_rest.pid with regard to their creationdataand

creation time. That way, changes made incorrectly in the EDIABAS files can be detected and

corrected.

After running, the VC Tool creates a text file called VC.log in which the comparison is given

with the specific results. This file is stored in the directory where the VC Tool is found

(C:\EDIABAS).

4.24 What is the KVP Editor?

KVP stands for continuous improvement process. The KVP Editor can be called when using

the INPA Tool. This is mainly used in reworking and in the plant. Here, the user has the

possibility to enter his name and telephone number and then enter an error description and

improvement request and then to send the form directly to the person responsible at BMW.





Source:http://blog.obdexpress.co.uk/2017/08/04/how-to-use-bmw-inpa-ediabas-5-0-2/





www.obd2eshop.com

Posted by: OBDexpress.co.uk at 06:30 AM | No Comments | Add Comment
Post contains 7775 words, total size 213 kb.




What colour is a green orange?




227kb generated in CPU 0.5557, elapsed 0.6182 seconds.
35 queries taking 0.226 seconds, 115 records returned.
Powered by Minx 1.1.6c-pink.